BLFYB - CALIBRATION GAS CO45-55 PPM IN AIR, 51-2277

  • MSDS: BLFYB
  • Manufacturer: BACHARACH INC
  • Product Name: CALIBRATION GAS CO45-55 PPM IN AIR, 51-2277
  • National Stock Number: 6830-00N018765
Product Identification

Product ID:CALIBRATION GAS CO45-55 PPM IN AIR, 51-2277
MSDS Date:02/13/1991
FSC:6830
NIIN:00N018765
MSDS Number: BLFYB

Responsible Party
BACHARACH INC
625 ALPHA DRIVE
PITTSBURGH, PA 15238
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 412-963-2223

Cage: 05083

Contractor
BACHARACH INC
PITTSBURGH, PA 15238 US

Telephone: 412-963-2130

Cage: 05083

Ingredients

CARBON MONOXIDE

CAS: 630-08-0

RTECS: FG3500000

Fraction By Weight: 0.005%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM; 9293


AIR, COMPRESSED

Fraction By Weight: 99.995%


SINCE THIS GAS IS ODORLESS, AREAS OF USE OR WHERE

RTECS: 9999999ZZ


TO ASSURE THAT THE CONCENTRATIONS ARE MAINTAINED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LC50(RAT): 1807 PPM/4HR
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) EYES & SKIN: NONE KNOWN OR
EXPECTED. INHAL: CO IS A CHEM ASPHYXIANT WHICH AFFECTS OXYGEN
TRANSPORT OF THE BLOOD. SYMP INCL HDCH, POUNDING HEART, DIZZ,
WEAKNESS, CONFUSN & NAUS. DEATH MAY RESUL T FROM INTENSE/PRLNGD
EXPOS. INGEST: NOT APPLIC. THIS MATL IS A GAS. (CHRONIC) EXPOS TO
LOW LEVS OF(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CO MAY ADVERSELY AFFECT CARDIOVASCULAR
SYSTEM. IRRITANCY: MATL IS NOT IRRIT TO TISS. SENSIT: NOT A
SENSITIZER. REPRO TOX: CO HAS BEEN RPTD TO CAUSE ADVERSE EFTS ON
FERTILITY IN SOME ANIMAL ST UDIES. TERATOGENICITY: CO HAS BEEN
RPTDTO CAUSE DEVELOPMENTAL ABNORMALITIES & FETAL TOX IN ANIMAL
STUDIES. (SUPP DATA)
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING
RESPIRATORY DISEASE AND SMOKERS MAY BE AT INCREASED RISK FROM
EXPOSURE.

First Aid

First Aid:EYE & SKIN: NONE NEEDED. INHAL: RESCUERS SHOULD BE AWARE OF
HAZARD AND WEAR SCBA. REMOVE VICTIM FROM AREA TO FRESH AIR, GIVE
ARTIFICIAL RESPIRATION, GET MD IMMEDIATELY. INGEST: NONE NEEDED.

Fire Fighting

Flash Point:NON-FLAMMABLE
Lower Limits:12.5%
Upper Limits:74% (CO)
Extinguishing Media:THIS GAS IS NOT FLAMMABLE. COOL EXPOSED CNTNRS WITH
WATER. USE MEDIA SUITABLE FOR SURROUDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROT EQUIP
. USE SHIELDING TO PROTECT FROM CYLINDER EXPLOSION.
Unusual Fire/Explosion Hazard:CONC OF CO IS COMPRESSED AIR AT HIGH PRESS WILL ACCELERATE BURNING OF OTHER
MATLS. GAS CYL EXPSD TO HEAT/FLAME MAY VENT RAPIDLY/EXPLD.

Accidental Release

Spill Release Procedures:EVACUATE AREA, WEAR NIOSH/MSHA APPROVED
POSITIVE PRESSURE SCBA AND MOVE LEAKING CYLINDER TO A HOOD OF
OUTDOOR LOCATION. ALLOW GAS TO DISSIPATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE NEAR HEAT/OPEN FLAME.
EXPOS TO TEMPS >125F MAY CAUSE RUPTURE. SECURE CYL-DO NOT DROP.
OUTDOOR STORAGE PREFERRED.
Other Precautions:DO NOT BREATHE GAS. CONTENTS UNDER PRESS. DO NOT
PUNCTURE. NEVER THROW CNTNR IN FIRE/INCINERATOR. KEEP CYL SECURED.
DO NOT DROP/DMG. USE PRESS REGULATOR & CHECK VALVES AS APPROP. KEEP
CYL AWAY FROM HE AT, FLAMES & ALL IGNIT (SEE SUPP DATA)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVED POSITIVE PRESS SCBA FOR EMER
USE. DO NOT BREATHE GAS. SELECTION OF RESP PROT DEPENDS ON
CONTAMINANT TYPE, FORM & CONC. SELECT IN ACCORDANCE WITH OSHA
1910.134 AND GOOD INDUSTRIAL HY GIENE PRACTICE.
Ventilation:LOCAL EXHAUST OR ADEQUATE GENERAL VENTILATION TO MAINTAIN
CONCENTRATION BELOW THE PEL.
Protective Gloves:LEATHER GLOVES RECOMMENDED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SEE OTHER PRECAUTIONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP:MUTAGENICITY:CO IS MUTAGENIC IN SOME TEST SYSTEMS.
SYNERGISTIC EFTS:METHYLENE CHLORIDE IS METABOLIZED TO CO IN THE
BODY & INCREASES TOXIC EFT OF CO EXPOS. OTHER PREC: SOURCES. FOR
ADDT NL HNDLG REC ON COMPRESSED GAS CYL, CONSULT COMPRESSED GAS
ASSOC PAMPHLET P-1. PROT FROM HEAT & PHYS DMG. (SEE ING 3)

Chemical Properties

HCC:G3
Boiling Pt:B.P. Text:-317F,-194C
Vapor Density:1
Spec Gravity:0.8
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS, TASTELESS COMPRESSED GAS IN
CYLINDERS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:AVOID HEAT OR FLAMES.
Hazardous Decomposition Products:NONE KNOWN.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL LOCAL, STATE AND
FEDERAL REGULATIONS. DO NOT INCINERATE CYLINDER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.